W. BERKAN, A. DUSZA, L. MICHALSKI, A. MICHALSKI, S. SCRAFIN, "Certain problems of smoothing reactor optimisation for DC link of indirect frequency converter", 1996.
Copyright - [Précédente] [Première page] [Suivante] - Home

Article : [SHEET476]

Info : INSPEC ANSWER 25, le 18/10/2000.

Titre : W. BERKAN, A. DUSZA, L. MICHALSKI, A. MICHALSKI, S. SCRAFIN, Certain problems of smoothing reactor optimisation for DC link of indirect frequency converter, 1996.

Cité dans : [DATA203] Recherche sur les mots clés CONVERTER et INDIRECT, octobre 2000.
Cité dans : [CONF084] SPEEDAM, International Symposium on Power Electronics, Electrical Drives, Automation and Motion, mai 2009.
Auteur : Berkan, W.
Auteur : Dusza, A.
Auteur : Michalski, L.
Auteur : Michalski, A.
Auteur : Scrafin, S. (Electrotech. Inst., Warszawa, Poland)

Source : Symposium on Power Electronics, Industrial Drives Power Quality, Traction Systems.
Proceedings : Speedam Napoli, Italy: Univ. 'Federico II', 1996. p.A1-11-16 of 2 vol. (x+684+34) pp.
Références : 4 refs.
Availability : Prof A Del Pizzo, SPEEDAM, c/o Dip di Ingegneria Elettrica, Universita 'Federico II', via Claudio 21, I-80125 Napoli, Italy.
Conference : Capri, Italy.
Date : 5-7 June 1996
Document_Type : Conference Article
Treatment_Code : Theoretical
Info : Country of Publication : Italy
Language : English
Stockage : annulé INIST, le 13/11/2000

Abstract :
The paper presents methods of optimisation of the reactors used in the DC link of indirect thyristor frequency converters
for induction heating systems. These reactors should keep direct current ripple below the assumed level, diminish backfeed
of inverter frequency components into the line and protect the rectifier under fault conditions (output short-circuits and
commutation failure). Computer simulation is used for calculations. The L=f(i) characteristics of the reactor are calculated,
which assure constant per unit value of current ripple within the whole range of the load (for constant value of direct
voltage). The damping of backed harmonics of inverter operating frequency is discussed, with special attention paid to line
side connected capacitor banks. It is demonstrated that DC link reactor and electronic overcurrent protection systems fully
protect inverter thyristors against short circuits.

Accession_Number : 1998:5883561


Mise à jour le lundi 10 avril 2023 à 18 h 59 - E-mail : thierry.lequeu@gmail.com