Article : [SHEET252]
Info : INSPEC Answer Number 3, le 16/03/2000.
Titre : Service problems of power electronics circuits with GTO thyristors, 1998.
Cité dans : [DATA050] Recherche sur l'auteur S. JANUSZEWSKIAuteur : Januszewski, S.
Source : Prace Instytutu Elektrotechniki (1998) vol.46, no.198,
Année : 1998
Pages : 5 - 28
References : 6 refs.
Published : by Inst. Elektrotech., Warszawa
CODEN : PIELA4
ISSN : 0032-6216
SICI : 0032-6216(1998)46:198L.5:SPPE;1-U
Document_Type : Journal
Treatment_Code : Experimental
Info : Country of Publication : Poland
Language : Polish
Stockage :
Abstract :
Determination of thyristor ratings and dynamic phenomena during GTO
thyristor turn-off are discussed. There is a current density inhomogeneity
in such circumstances. If gives some current concentration in peripheral
segment groups. An oscillation GTO turn-off process is described. A
modificated GTO overvoltage protection, that eliminates resistors from
snubber circuits, is presented. Some difficulties dealing with an assembly
of GTO thyristors in converters are related.
Accession_Number : 1999:6238164