Fiche : [ART584]
Titre : S. TEBBANI, E. GODOY, Y. LOUVAIN, K. SAUTEREAU, Synchronization of the inverter voltage supply in order to reduce the residual output ripple, EPE'2003, September 2003, Toulouse, France.
Cité dans : [DIV213] EPE'2003, European Conference on Power Electronics and Applications, Toulouse, France, du 2 au 4 septembre 2003. Cité dans : [CONF004] EPE, European Conference on Power Electronics and Applications, juillet 2012. Cité dans : [DIV376] Recherche sur l'auteur Emmanuel GODOY, septembre 2004.Auteur : Sihem Tebbani - (1)
Date : du 2 au 4 septembre 2003
Congrés : 10th European Conference on Power Electronics and Applications
Lien : private/2003PP0466.pdf - 9 pages, 380 Ko.
Vers : Bibliographie
Adresse : (1) Supélec - Service Automatique - 3 rue Joliot Curie, Plateau de Moulon, F91192 Gif sur Yvette Cedex / France
Fax : +33 [0]1 69 85 12 34
Phone : +33 [0]1 69 85 13 75
Lien : mailto:Emmanuel.Godoy@supelec.fr
Phone : +33 [0]1 69 85 13 86
Lien : mailto:Sihem.Tebbani@supelec.fr
Adresse : (2) Faiveley - Z.I. du Bois de Plante F37700 La Ville aux Dames / France
Phone : +33 [0]2 47 32 57 04
Fax : +33 [0]2 47 32 56 61
Lien : mailto:Y.Louvain@Faiveley.com
Lien : mailto:K.Sauterau@Faiveley.com
Abstract :
This paper deals with the study of an inverter system, used in train supply application. This system has been modelized and a control law has been determined so that the imposed specifications are respected [1].
However, when using an AC rectified inverter supply, it has been noticed residual low-frequency ripple on the output voltage of the machine. This ripple appears especially when the output inverter frequency is close to that of the AC supply.
This paper shows that this phenomenon can be restricted by the synchronization of the frequencies of the inverter and of the voltage supply. The supply voltage characteristics will be estimated using Kalman filter.
This strategy was tested on the real system and has been found very efficient. Some numerical results will illustrate the efficiency of this strategy.
Keywords : Inverter, output low-frequency ripple, Kalman filter, inverter frequency synchronization.
Bibliographie |
[1] : [ART433] E. GODOY, Y. LOUVAIN, K. SAUTEREAU, S. TEBBANI, Stability analysis of a constant-power inverter, EPE'2003, September 2003, Toulouse, France. [2] : [LIVRE349] J.M.D. MURPHY, F.G. TURNBULL, Power Electronic Control of AC Motors, Pergamon Press, 1988. [3] : [LIVRE034] N. MOHAN, T.M. UNDELAND, W.P. ROBBINS, Power Electronics - Converters, Applications and Design, John Wiley & Sons, 1995 second edition, 802 pages. [4] : [PAP158] ------- [5] : [PAP158] ------- [6] : [PAP158] -------
Mise à jour le lundi 10 avril 2023 à 18 h 47 - E-mail : thierry.lequeu@gmail.com
Cette page a été produite par le programme TXT2HTM.EXE, version 10.7.3 du 27 décembre 2018.
Copyright 2023 : |
Les informations contenues dans cette page sont à usage strict de Thierry LEQUEU et ne doivent être utilisées ou copiées par un tiers.
Powered by www.google.fr, www.e-kart.fr, l'atelier d'Aurélie - Coiffure mixte et barbier, La Boutique Kit Elec Shop and www.lequeu.fr.