Fiche : [ART433]
Titre : E. GODOY, Y. LOUVAIN, K. SAUTEREAU, S. TEBBANI, Stability analysis of a constant-power inverter, EPE'2003, September 2003, Toulouse, France.
Cité dans : [DIV213] EPE'2003, European Conference on Power Electronics and Applications, Toulouse, France, du 2 au 4 septembre 2003. Cité dans : [CONF004] EPE, European Conference on Power Electronics and Applications, juillet 2012. Cité dans : [DIV376] Recherche sur l'auteur Emmanuel GODOY, septembre 2004.Auteur : GODOY Emmanuel - (1)
Date : du 2 au 4 septembre 2003
Congrés : 10th European Conference on Power Electronics and Applications
Lien : private/2003PP0465.pdf
Adresse : (1) Supélec - Service Automatique - 3 rue Joliot Curie, Plateau de Moulon, F91192 Gif sur Yvette Cedex / France
Fax : +33 [0]1 69 85 12 34
Phone : +33 [0]1 69 85 13 75
Lien : mailto:Emmanuel.Godoy@supelec.fr
Phone : +33 [0]1 69 85 13 86
Lien : mailto:Sihem.Tebbani@supelec.fr
Adresse : (2) Faiveley - Z.I. du Bois de Plante F37700 La Ville aux Dames / France
Phone : +33 [0]2 47 32 57 04
Fax : +33 [0]2 47 32 56 61
Lien : mailto:Y.Louvain@Faiveley.com
Lien : mailto:K.Sauterau@Faiveley.com
Abstract :
This paper deals with the study of a constant-power inverter and its controllability analysis. This
process is used in train air-conditioning power supply. Because of the load at constant power, in the
absence of specific control law, this system is characterized by an unstable behaviour. This problem
can be solved by adding a passive device, however this solution leads to losses of power. An
alternative and more interesting solution is to introduce an active solution by means of closed loop
regulation, however some internal variables of this system have a small degree of commandability,
which makes difficult the achievement of this solution. First, the system is studied: modelling, stability
and controllability analysis, study of passive stabilisation. Then the active control law developed is
presented. More precisely, a methodology is described for the design of a control law, which permits
on one hand to stabilize the inverter without adding any complementary passive device, and on the
other hand to let the output voltage track a sinusoidal reference signal. Finally, some numerical results
are given to show the efficiency of such a law.
Keywords : Inverter, pole placement, LQ control law, controllability, inverter controllability.
Bibliographie |
[1] : [LIVRE349] J.M.D. MURPHY, F.G. TURNBULL, Power Electronic Control of AC Motors, Pergamon Press, 1988. [2] : [ART321] J. LAEUFFER, E. GODOY, T. PLANAS, B. LORCET, D. SARDANAC, A control analysis and closed-loop design for series-parallel resonant converters, EPE'97. [3] : [PAP158] ------- [4] : [ART584] S. TEBBANI, E. GODOY, Y. LOUVAIN, K. SAUTEREAU, Synchronization of the inverter voltage supply in order to reduce the residual output ripple, EPE'2003, September 2003, Toulouse, France.
Mise à jour le lundi 10 avril 2023 à 18 h 47 - E-mail : thierry.lequeu@gmail.com