Article : [SHEET365]
Info : COMPENDEX Answer Number 5, le 19/06/2000.
Titre : Direct cooling for big GTOs. (power thyristors).
Cité dans : [DATA146] LTN, Laboratoire des Technologies Nouvelles, INRETS, Arcueil, France.Auteur : Coquery, G. (INRETS
Source : RGE Rev Gen Electr n 2 Feb 1988 p 14-21
CODEN : RGELAC
ISSN : 0035-3116
Année : 1988
Document_Type : Journal
Treatment_Code : Application; Experimental
Stockage :
Abstract :
Using 50 to 75 mm GTO allows a reduction of the number of power
components and of total losses in traction equipment.However, the
GTO itself is not easy to cool due to its reduced cathode surface
and mechanical difficulties for its correct pressing.Also, the
concentration of losses in one component, creates problems of
spreading them over the surface of big fins.A special device,
adapted to these requirements, is presented.It allows one to mount
an isolated GTO, without liquid, into one single faced fin.The tests
have been performed up to 1,500 W of losses for a 50 mm
component.(Edited author abstract).
References : 7 Refs.
Accession_Number : 1988(11):157165